FINECO Encapsulated Steel Data Center Raised Floor
Hevi-Diuti Akses Floa bilong ol Data Senta, Seva Rum na Ol Bikpela IT Fasiliti
FINECO Encapsulated Steel Raised Floor em i wanpela 'modular access flooring system' we ol i wokim bilong ol data senta, ol 'server room', na ol teknikel envairomen we i nidim 'structural load performance', 'underfloor service access', na longpela taim.
Dispela sistem i gat ol 'steel panel' we i pas olgeta, wanpela 'engineered core', na ol 'steel pedestals' we yu ken stretim. Dispela i kamapim wanpela ples aninit long plua we ol manmeri i ken go insait long en bilong tilim pawa, data kebol, na ol infrastraksa bilong mekim kol taim em i sapotim ol bikpela IT ikwipmen.
Teknikel Spesifikasen
|
Paramita |
Spesifikasen |
|
Kain Prodak |
Encapsulated Steel Raised Access Floor |
|
Namba wan aplikesen |
Ol Data Senta, Ol Seva Rum, Ol Telekom Fasiliti |
|
Standet Sais bilong Panel |
600 × 600 mm |
|
Tiknes bilong Panel |
30 mm - 35 mm (Yu ken senisim) |
|
Panel Konstraksen |
Ol 'Welded Steel Top & Bottom Sheets' we i stap insait olgeta |
|
Bikpela samting |
Hai-Densiti Patikel Bod / Simen As |
|
Pinis bilong pes |
HPL / PVC / ESD Vinyl / Bare Steel |
|
Hevi bilong Panel |
Klostu. 12 - 15 kg/m2 |
|
Konsentreted Lod |
3.0 kN - 4.5 kN (Klas 1 – Klas 3) |
|
Yunifom Distributed Lod |
10 - 15 kN/m2 |
|
Hait bilong plua pinis (FFH) |
150 mm - 1500 mm |
|
Pedestal Andastraksa |
Strongpela 'Galvanized Steel' wantaim ol 'Stringers' |
|
ESD Pefomens |
Dissipative (106 - 109 Ohms) o Conductive (104 - 106 Ohms) |
|
Klasifikasen bilong paia |
Flame Spread Class A / Class 0 |
|
Ol Standet Bilong Bihainim Lo |
EN 12825 / CISCA Seksen 5 / ASTM E84 |
Prodak straksa
Enkapsulet Panel Asembli:I gat ol 'welded steel sheets' antap na daunbilo we i karamapim wanpela 'engineered core' we i gat bikpela 'density', na i save lukautim arere bilong en, i no inap kisim wara, na i save stap strong longpela taim.
Ol 'Steel Pedestals' we yu ken stretim:I gat ol strongpela 'galvanised steel base pletes' na ol 'vertical threaded stems' we i larim stretpela 'floor leveling' na pinisim 'floor heights' stat long 150 mm i go inap 1500 mm.
Grid-Loking Pedestal Heads:Lukim gut ol wanwan panel insait long wanpela gutpela 600 × 600 mm modular grid na tu yu mas meksua olsem hevi bilong en i go long 'structural slab'.
Ol 'Steel Stringers' we yu ken makim:Ol 'snap-on o bolted steel stringers i save konektim ol het bilong ol 'pedestal' long strongim 'lateral stability', 'torsional rigidity', na 'rolling load performance' bilong ol hevi ikwipmen zon.
Ol gutpela samting bilong prodak
Ful Steel Enkapsulesen:Ol 'steel sheets' we i stap antap na daunbilo i save lukautim as bilong en long wara, bikpela bagarap, na bagarap taim ol i mekim wok mentenens planti taim.
Integreted Load Stability:Ol i bungim ol 'precision- panels, ol 'steel pedestals' we yu ken stretim, na ol 'stringers' we yu ken putim i mekim na ol i no inap long sakim ol 'rolling' na 'concentrated server rack loads'.
Rapid Maintenance Access:Ol wanwan panel i save apim hariap tru long yusim ol 'suction lifters', na dispela i larim ol 'cable re-routing o ol ikwipmen apgret hariap na i no bagarapim ol infrastraksa klostu.
Gutpela Airflow Menesmen:Ol strongpela panel i save wok gut wantaim ol 'perforated' o 'adjustable grille panels' bilong sapotim ol stretpela 'underfloor cooling' strateji.
Strongpela kwaliti asurens:Ol i wokim aninit long ol 'multi-stej kwaliti kontrol we i karamapim 'steel stamping', 'encapsulation sealing', na 'dimensional tolerance checks'.
Ol aplikesen bilong prodak
Ol 'Hiperscale' na 'Colocation Data Centers':I givim sapot bilong ol ikwipmen we i gat bikpela -densiti na ol gutpela 'layout' bilong senisim ol 'server configuration'.
Ol Rum bilong Entaprais Seva:I givim wanpela gutpela, oganais pletfom bilong ol IT infrastraksa na ol pawa distribusen yunit bilong ol kampani.
Telekom na Netwok Fasiliti:Lukautim ol bikpela 'fiber-optic cabling na ol hevi 'communication hardware'.
Ol Rum Bilong Kontrol na Ol Spes Bilong Teknikel:Mekim gutpela sevis integresen na isi mentenens ekses long 24/7 misin-kritikal operesen.
Menesmen bilong Airflow & Andafloa Voids
Ol ples nating aninit long plua:I gat ol bikpela -pawa konduit, ol kebol trei, na ol 'busbar'.
Ol rot bilong pulim win:Ol strongpela panel i bung wantaim ol 'perforated steel panel' (25% i go inap 50% op eria) o ol 'grille panel' we yu ken stretim long mekim kol aninit long plua na hot/kol aisle kontenmen.
Kwaliti Kontrol na Ekspot Lojistiks
Precision Manufacturing:Strongpela 'multi-stej inspeksen i karamapim 'steel stamping', 'automated encapsulation', 'flatness', na 'load testing'.
Ekspot-Greid Pakejing:Ol i save pasim ol 'steel panel' long wara na putim long 'pallet' bilong stopim bagarap long arere taim ol i salim ol kontena i go long ol narapela kantri (FCL/LCL).
Ol Askim Planti Taim
Q: Wanem samting em i wanpela 'encapsulated steel raised floor'?
A: Em i wanpela 'modular access floor panel' we i gat ol gutpela 'welded top' na 'bottom steel sheets' we i karamapim wanpela 'engineered core', na ol i putim long ol 'steel pedestals' we yu ken stretim long kamapim wanpela 'accessable underfloor service void'.
Q: Sistem inap long sapotim ol hevi 'server rack'?
A: Yes. Ol i wokim dispela sistem bilong ol hevi 'concentrated' na 'rolling' lod. Ol i save skelim wok bilong en olsem wanpela bung bilong ol panel, pedestal, stringa, na 'structural slab' bilong makim ol hevi bilong ol ikwipmen.
Q: Ol panel we i gat win i stap bilong mekim kol?
A: Yes. Ol strongpela panel i ken bung wantaim ol 'perforated steel panel' (25% i go inap 50% op eria) o ol 'grille panel' we yu ken stretim long stretim ol samting bilong kol aninit long plua.
Q: Dispela plua i gutpela long ol ples we i gat ESD-sensitiv?
A: Yes. Ol konfiguresen i ken i gat ol 'conductive' o 'dissipative' pes pinis wantaim ol 'grounding' opsen bilong lukautim ol 'sensitive IT hardware' long 'electrostatic discharge'.
Q: Wanem infomesen yu nidim long kisim wanpela kwotesen?
A: Plis givim olgeta eria bilong projek (m2), Hait bilong plua (FFH), 'load capacity' yu laikim, 'surface finish' yu laikim, 'ventilation ratio', na ples bilong go long en.
Hot Tag: 'encapsulated steel data center raised floor', Saina 'encapsulated steel data center raised floor' ol man bilong wokim ol samting, ol saplaia, faktori