Ol i wokim bilong ol nupela samting, na FINECO's data senta i gat 'raised access flooring system' i gat gutpela strong, 'seamless cable management', na i no inap long karim hevi. Modular konstraksen i mekim na ol i ken putim hariap na ol i ken stretim gen. Em i gat ol samting we i no inap senis na i no inap long paia, na dispela i mekim na ples i stap gut na i gat gutpela oganaisesen. Em i gutpela tru long ol data senta, opis, na ol ples bilong indastri-i mekim wok i kamap gutpela na luk nais wantaim wanpela gutpela rot bilong stretim hevi.
Spesifikasen bilong prodak
|
Model |
Konsentreted Lod |
Impak Lod |
Laspela lod |
Yunifom Lod |
Roling Lod (N) |
||
|
LB |
N |
N |
N |
N/㎡ |
10-pela taim |
10000 taim |
|
|
FS800 |
800 |
3560 |
536 |
10680 |
16100 |
3560 |
2670 |
|
FS1000 |
1000 |
4450 |
670 |
13350 |
23000 |
4450 |
3560 |
|
FS1250 |
1250 |
5560 |
780 |
16680 |
33000 |
5560 |
4450 |
|
FS1500 |
1500 |
6660 |
1005 |
19980 |
34500 |
6675 |
5340 |
|
FS2000 |
2000 |
8900 |
1340 |
26700 |
46000 |
8900 |
7120 |
* Folem ol 'test procedures' bilong CE& CISCA long ol 'Access Floors'
600*600mm/24'*24' (610*610mm) i stap
Prodak samting na aplikesen
Data senta bilong FINECO i gat 'raised access flooring system' em ol i wokim bilong inapim ol infrastraksa nid bilong ol moden fasiliti. Ol i wokim dispela sistem long strongpela -, anti-ain we i no inap bagarap na i gat ol 'coatings' we i no inap kukim, na i gat gutpela strong bilong karim hevi na i stap longpela taim. Modular disain i mekim na ol i ken putim hariap, isi long stretim gen, na ol i ken yusim ol samting aninit long plua, na dispela i mekim wok i kamap gutpela moa. Ol 'integrated cable management channels' i save strongim 'airflow' na stretim pawa/data 'cabling' na tu i save daunim hevi. Em i gutpela tru long ol ples we i gat planti salens olsem ol data senta, ol indastrial fasiliti, ol rum bilong bosim wok, na ol leboretori, ol plua we ol i wokim long ain i mekim sefti, fleksibiliti, na bihainim ol intanesenel standet, na inapim ol bikpela nid bilong spes wantaim liklik wok mentenens.
Ol ditel bilong prodak

Ol i wokim dispela data senta bilong FINECO long mekim gutpela wok, na i gat ol gutpela samting bilong en. Ol 'ESD edge trims' i save givim gutpela 'conductivity' na 'static dissipation' long olgeta hap bilong plua. Olgeta sistem i save kisim strongpela 'epoxy powder-coated anti-rust tritmen, na dispela i save lukautim ol long 'corrosion' taim ples i wetwet o hatpela taim. Planti anti-static laminate (HPL, PVC, ceramic) i larim ol i ken senisim lukluk bilong ol na holim 10^4–10^9Ω resistens bilong pes. Ol 'reinforced bolted stringers' i save strongim 'structural stability', na inap long karim ol hevi inap long 890kg. Ol 'fire-rated cores i bihainim ASTM E84 Klas 1 standet. Ol arere bilong 'gasket- we i gat 'sealed' i kamapim ol rum we win i no inap go insait long en bilong klinim rum o long ol samting we i gat presa, na dispela i soim olsem sistem inap long mekim planti wok long sait bilong ol teknikel spesifikasen.
Kwalifikesen bilong Prodak

Ol i wokim long gutpela mak bilong kwaliti na strong bilong en, na data senta bilong FINECO i stat wantaim ol nambawan samting na wok bilong wokim ol samting stret. Ol bikpela samting i yusim ol 'high-grade ST14 na SPCC steels, we i gat nem long strong bilong en, i no inap long bagarap, na i no inap long kamap, na i save mekim gutpela wok aninit long ol hevi.
Inkoporesen bilong laitweit fom simen i save strongim wok bilong en long daunim hevi bilong en na givim gutpela 'thermal insulation', 'sound absorption', na grinpela samting. Prodaksen i dipen long ol strongpela, hai-ton pres we i save putim wankain presa na sepim gut, na rausim ol hevi bilong ol samting na mekim wok i kamap stret.


Taim ol i yusim ol gutpela samting na ol 'industrial-gred' ikwipmen, dispela i save kamapim ol prodak we i winim ol 'industrial norms' long sait bilong strong bilong en, wok bilong en, na wok bilong en, na i inapim ol strongpela askim bilong ol kastoma.
Siping na Pakej


FAQ
Q: 1. Mi yet inap long putim wanpela 'data center raised access flooring system'?
A: Maski DIY instolesen em i gutpela long ol simpol disain, em i gutpela long makim profesenel instolesen long ol kompleks disain. Struktural integriti, kebol menesmen, o sefti i ken bagarap sapos ol i no bungim gut.
Q: 2. Wanem em i 'load capacity' bilong wanpela 'data center raised access flooring system'?
A: I gat ol senis long 'load capacity', tasol ol standet sistem inap long karim 662 i go inap 2000 paun long wan wan skwea fut (psf). Long ol ples we i gat planti manmeri olsem ol data senta, yu ken nidim 2000+ psf. Sekim ol instraksen bilong man i wokim dispela samting long ol spesifik instolesen.
Q: 3. Wanem ol samting ol i wokim long 'data center raised access flooring system'?
A: Ol i save wokim ol panel long ain wantaim simen o 'laminate' antap, o aluminium bilong daunim hevi bilong en. I gat tu ol kain 'woodcore' na 'calcium sulphate core'. Ol i save wokim ol 'pedestal' na ol sapot long ain o aluminium. Ol 'anti-static coatings i save stap long ol ples we i gat ol ilektronik ikwipmen bilong stopim 'static discharge'.
Q: 4.Wanem laipspan bilong wanpela data senta we i gat 'raised access flooring system'?
A: Laip ekspektesen bilong wanpela data senta we i gat 'raised access flooring system' i save kamap long gutpela bilong ol samting na wok mentenens ol i mekim. Em inap long stap moa long 10-pela yia.
Q: 5. We mi ken painim moa risos o sapot?
A: Toktok wantaim data senta bilong yu we i gat 'raised access flooring system provider' long kisim ol teknikel manuel, ol instolesen tutorial, o ol in-konsaltesen. Ol ogenaisesen olsem BICSI (Building Industry Consulting Services International) i save givim ol gutpela gutpela pasin na trening risos tu.
Hot Tag: data senta i go antap long floa sistem, Saina data senta i go antap long floa sistem ol man i wokim, ol saplaia, faktori